POLICY REPORT
                           DEVELOPMENT AND BUILDING

                                           Date:  December 28, 1995
                                           Dept. File No. 95019 TWP


   TO:       Vancouver City Council

   FROM:     Director of Land Use and Development

   SUBJECT:  CD-1 Rezoning - 5625 Senlac Street


   RECOMMENDATION

        A.   THAT  the   application  by   Neale   Staniszkis  Doll   Adams
             Architects, to  rezone 5625  Senlac Street (Lots  7-10, 17-20;
             Blocks 44, 45; D.L. 37 Group 1; Plan 2426) from  RS-1 to CD-1,
             to permit four-storey multiple  dwellings at a maximum density
             of 1.3 Floor  Space Ratio,  be referred to  a Public  Hearing,
             together with:

             i)   plans received November 8, 1995;

             ii)  draft CD-1 By-law provisions,  generally as contained  in
                  Appendix A; and

             iii) the  recommendation  of  the  Director of  Land  Use  and
                  Development  to approve, subject  to conditions contained
                  in Appendix B.

             FURTHER THAT the Director of  Legal Services be instructed  to
             prepare the necessary CD-1  By-law for consideration at Public
             Hearing.

        B.   THAT, subject to approval of the rezoning at a Public Hearing,
             the  Subdivision By-law be amended  as set out  in Appendix D;
             and

             FURTHER THAT the  Director of Legal Services  be instructed to
             bring forward the amendment to  the Subdivision By-law at  the
             time of enactment of the Zoning By-law.

   GENERAL MANAGER'S COMMENTS

        The General Manager of Community Services RECOMMENDS approval  of A
        and B.

   COUNCIL POLICY

   There is no Council policy directly relevant to this application. 
   PURPOSE AND SUMMARY

   This report assesses an  application to rezone eight RS-1  zoned parcels
   (presently developed  as a surface parking lot)  to CD-1, to develop two
   4-storey  multiple   dwellings  fronting  Senlac   and  Wessex  Streets,
   containing a total of 25 stacked  2-storey townhouse units and a  3-unit
   3-storey townhouse structure in an interior courtyard.  The south end of
   the courtyard would be open toward the  rear of six one-family dwellings
   on RS-1  zoned lots fronting  School Avenue.   This site  is immediately
   south  of the Kingsway  C-2 Commercial District.   A maximum  density of
   1.30  FSR and  a height of  15.5 m  (51 ft.) are proposed.   Lower units
   would  have street entries with front setbacks  averaging 4.9 m (16 ft.)
   and rear access to the secured courtyard.  Upper storey units would have
   their  principal  access   from  the  courtyard.    Staff   support  the

   application and  accompanying scheme which  provides additional dwelling
   units in a desirable form of multi-family housing.

   DISCUSSION

   Use  Multiple dwellings are considered the most appropriate  use of this
   site.   Additional commercial zoning  is not desirable  because there is
   abundant  capacity  for commercial  expansion  within  the existing  C-2
   Commercial  District along  Kingsway.   The adjoining  and adjacent  C-2
   zoned  sites  present  a  context  better suited  to  multiple  dwelling
   development forms than to one-family dwellings.

   Density  The proposed density  is 1.30 FSR.  After dedication  of a lane
   between the  site and  the northerly  adjacent commercial  district, the
   effective density is approximately 1.50 FSR.  This density is considered
   moderate  in  relation to  the density  permitted in  C-2.   However, to
   accommodate this density immediately  adjoining RS-1 sites to the  south
   requires careful  attention to  transitional scale  and elements  of the
   design adjoining the RS-1 sites.

   Form   Several aspects of the  design of this proposed  development have
   been  the subject of intense  discussion.  The  initially proposed four-
   storey form only  3 m (10 ft.)  from the RS-1 rear  yards was considered
   clearly out of scale with the context.  The initial scheme also proposed
   a raised  courtyard and  wall rising 3 m  above the adjoining  RS-1 rear
   yards.   The townhouse structure  in the courtyard  was also of  a scale
   which unacceptably reduced privacy and  light into street fronting units
   at the  north end of  the court yard.   Staff  had security concerns  as
   well, regarding access to both north and south ends of the courtyard.

   In response to staff  concerns, revised plans show stepping of the south
   end of the buildings and court yard to levels complementary to the scale
   of RS-1 development to the  south.  The 3-storey townhouse structure  in
   the courtyard has been lowered  by 0.6 m (2  ft.), narrowed by 1.2 m  (4
   ft.), had side windows removed and  the roof hipped to improve light and
   privacy  to  northerly street  fronting  units.   However,  to  preserve
   sunlight and openness for  potential future dwelling units to  the north
   in the C-2 District and maintain  a comparable scale, the height of this
   3-storey courtyard  structure should  be further reduced,  as stated  in
   Appendix B - Proposed Conditions of Approval.

   A  former post office structure occupies a  portion of the land required
   for lane dedication and would be  immediately abutting the north side of
   this  development (Note Plans: Appendix C).  The applicant now indicates
   that this  portion of the old post office structure will be removed from
   the lane dedication, and  this demolition is recommended as  a condition
   to be met prior to rezoning enactment.
   CONCLUSION

   Planning  staff conclude  that  the amended  rezoning application  would
   provide a desirable type of  multiple dwelling in a form which  fits the
   context of  a transition  from  C-2 Commercial  to  an RS-1  One  Family
   Dwelling District.  Planning staff recommend approval.

                                     * * *                       APPENDIX A


                         DRAFT CD-1 BY-LAW PROVISIONS
                              5625 Senlac Street


   Use
                -  Multiple dwellings  containing a maximum of  28 dwelling
                   units.

   Density

                -  Maximum floor space ratio of  1.30, based on calculation
                   provisions of the RM-4 District Schedule.

   Height

                -  A  maximum  of  14.8  m  (48.5  ft.)  for  the  3-storey
                   courtyard   structure  (reduced   to  reflect  condition
                   b(ii), Appendix B),

                -  A  maximum of  13.9  m  (45.5 ft.)  for  street-fronting
                   multiple dwellings, and

                -  A  maximum  of 10.7  m (35  ft.)  for roofs  within 12 m
                   (39.3 ft.) of the south property line.


   Setback

                -  A minimum setback varying from  4.5 m (15 ft.) to  5.2 m
                   (17  ft.) from  the  front property  line on  Wessex and
                   Senlac Streets, and

                -  A minimum  setback of  3.0 m  (9.8 ft.)  from the  south
                   property line.

   Parking

                -  Per Parking By-law for RM-4/4N District.   The small car
                   ratio is not to exceed 25%.

   Acoustics

                -  Per RM-4N District Schedule.
                                                                 APPENDIX B
                                                                Page 1 of 3


                        PROPOSED CONDITIONS OF APPROVAL

                              5625 Senlac Street



   (a)    That the proposed form of development  be approved by Council  in
          principle, generally as prepared by Neale Staniszkis  Doll Adams,
          Architects,  and  stamped  "Received  City  Planning  Department,
          November  8, 1995,  provided  that the  Director of  Planning may
          allow  minor  alterations  to  this  form  of   development  when
          approving  the detailed scheme of development as  outlined in (b)
          below.

   (b)    That, prior  to approval by Council  of the  form of development,
          the applicant shall obtain approval of a  development application
          by the Director of  Planning, who shall have particular regard to
          the following:

          (i)    deletion from  the plans of proposed temporary landscaping
                 on the land to be dedicated as lane;

          (ii)   design  development to reduce the overall height of the 3-
                 storey courtyard structure by 0.7 m (2.30 ft.);

          (iii)  design development to the north (proposed  lane) elevation
                 wall  to  reduce it's  impact by  reducing the  solid wall
                 height  and  adding a  transparent  guard  at  the  second
                 floor;

          (iv)   design development  to  the  north elevation  for  greater
                 visual surveillance into the parking areas;

          (v)    indication of a security  grille at the  parking entry  on
                 the floor plan;

          (vi)   confirmation of material for the north elevation.   Split-
                 face  concrete  block  with  some  coursing pattern  would
                 achieve this;

          (vii)  design  development to  provide security  measures for the
                 second floor  courtyard and  the elevator  lobby entry  at
                 the northeast corner at the lane;

          (viii) provision of  wall and  rooftop screening  for the  refuse
                 and recycling areas;
                                                                 APPENDIX B
                                                                Page 2 of 3



          (ix)   provision of a landscape plan;

          (x)    provision of  east and  west elevations  for the  3-storey
                 courtyard structure;

          (xi)   provision of  a large scale  cross section indicating  the
                 relationship between the  3-storey courtyard structure and
                 the adjacent units;

          (xii)  design development to parking  area finishes and  lighting
                 in accordance with Sections 4.8.3 and 4.12 of  the Parking
                 By-law and  including a "white  painted finish"  including
                 the underside of the suspended concrete slab; 

          (xiii) additional  individual   suite  entry   lighting  must  be
                 provided;

          (xiv)  provision of recycling and garbage facilities;

          (xv)   ramp grades  are not  to exceed  10% in  the first  20 ft.
                 from the  lane, and  manoeuvring aisle grade in  the upper
                 level of the parking area cannot exceed 6%;

          (xvi)  re-design of  the manoeuvring aisle into  stalls 9 and  10
                 in the lower level of parking; and

          (xvii) parking ramp entry from the lane to be 20 ft. wide.

   (c)    That,  prior to  enactment  of the  CD-1 By-law,  the  registered
          owner shall:

          (i)    consolidate Lots 7-10, 17-20; Block 44, 45;  D.L. 37; Plan
                 2426;

          (ii)   dedicate the  north  20 ft.  of  the  site for  lane,  and
                 adequate arrangements must be made for opening  and paving
                 the lane  at the applicant's cost.   The  lane will extend
                 from Senlac  to Wessex  Streets, therefore  access to  the
                 site will be from the new east/west lane; and

          (iii)  obtain a demolition  permit and execute demolition of  the
                 portion of the existing building that encroaches  upon the
                 land to be dedicated for lane;
                                                                 APPENDIX B
                                                                Page 3 of 3



          (iv)   make  arrangements   for  all   electrical  and  telephone
                 services to be undergrounded within and adjacent  the site
                 from the closest existing suitable service point; 

          (v)    execute a legal agreement satisfactory to the  Director of
                 Legal   Services   providing   that   owners    will   not
                 discriminate against  families with  children in the  sale
                 of their property; and

          (vi)   make arrangements  to  the  satisfaction  of  the  General
                 Manager  of  Engineering  Services  for the  provision  of
                 boulevard trees on Wessex Street.
                                                                 APPENDIX E

   APPLICANT, PROPERTY, AND DEVELOPMENT PROPOSAL INFORMATION


   APPLICANT AND PROPERTY INFORMATION 

            Street Address                    5625 Senlac Street
            Legal Description                 L 7-10, 17-20; Blocks 44, 45; D.L. 37; Plan 2426

            Applicant                         Neale Staniszkis Doll Adams Architects

            Architect                         same as above
            Property Owner                    KINIP Construction (Alan Ip); Awon Investment Ltd.; 416465 B.C. Ltd.

            Developer                         KINIP Construction


          SITE STATISTICS

                                                      GROSS                  DEDICATIONS                  NET

            SITE AREA                             .29 ha (.72 ac)          .03 ha (.09 ac)          .26 ha (.64 ac)

            FRONTAGE                             48.9 m (160 ft.)                 (on Senlac and on Wessex)
            DEPTH                               60.3 m (197.7 ft.)                 (from Senlac to Wessex)



          DEVELOPMENT STATISTICS
                                                                                                        RECOMMENDED
                                               DEVELOPMENT PERMITTED                                  DEVELOPMENT (if
                                               UNDER EXISTING ZONING       PROPOSED DEVELOPMENT       different than
                                                                                                         proposed)

            ZONING                                      RS-1                       CD-1                    CD-1

            USES                                     One Family             Multiple Dwelling                -

            DWELLING UNITS                               8                          28                       -
            MAX. FLOOR SPACE RATIO                      0.60                       1.30                      -

            MAXIMUM HEIGHT                         9.2 m (30 ft.)            15.5 m (51 ft.)         14.8 m (48.5 ft.)

            MAX. NO. OF STOREYS                        2-1/2                        4                        -
            PARKING SPACES                             8 - 16                       39                       -

            FRONT YARD SETBACK                     6 m (19.8 ft.)         Average 4.9 m (16 ft.)             -

            SIDE YARD SETBACK                      1.2 m (4 ft.)               3 m (10 ft.)                  -

            REAR YARD SETBACK                    13.6 m (44.5 ft.)            Interior Court                 -
                                                                             22.9 m (75 ft.)

                                                                                                                  
APPENDIX D
                                                                Page 1 of 2



                            ADDITIONAL INFORMATION


   Proposed Development  The site frontages on Senlac Street and on Wessex
   Street would each be developed with a four storey multiple dwelling
   containing stacked two-storey townhouses.  Although lower units have
   entries from the street, both upper and lower stacked townhouses open
   onto a secured interior courtyard.  Access to upper units is via the
   courtyard from the north end from parking below, or from the street at
   both ends.  The south end of the courtyard steps down to grade 5 m (16.6
   ft.) north of the RS-1 property line, allowing access to both streets
   via a landscaped strip of 3 to 5 m.  A 3-storey 3-unit structure is
   centred in the north end of the courtyard 24.4 m (80 ft.) from the RS-1
   property line.  There is a 4-5.3 m (13-17.3 ft.) separation between this
   structure and the 4-storey buildings.

   To provide a transition in scale and minimize intrusion, the two 
   street-fronting structures would both step down from 4 to 2.5 storeys as
   they approach the adjoining RS-1 District to the south.  This scheme
   provides average 4.9 m (16 ft.) front yards.

   Public Input  A notification letter was sent to nearby property owners
   on June 21, 1995 and rezoning information signs were posted on the site
   on June 28, 1995.  Two phone calls were received from residents and none
   came to City Hall to view plans.  Concerns focused on the adequacy of
   parking, given commercial parking congestion in the area.  No letters
   expressing opposition were received from nearby residents.

   Comments of the City Engineer   The City Engineer has no objection to
   the proposed rezoning, provided that the applicant complies with
   conditions as shown in Appendix B.

   Urban Design Panel Comment  The Urban Design Panel reviewed the proposal
   on June 7, 1995 and supports the proposed use, density and form of
   development.

   ENVIRONMENTAL IMPLICATIONS

   Nearby access to transit and commercial services may reduce dependence
   on use of automobiles.
                                                                 APPENDIX D
                                                                Page 2 of 2




   SOCIAL IMPLICATIONS

   The stacked townhouse form of development offers accommodation suited
   for families.  Otherwise, there are no major positive or negative social
   implications to this proposal.  There are no implications with respect
   to the Vancouver Children's Policy or Statement of Children's
   Entitlements.

   CONSEQUENTIAL AMENDMENT  

   If the proposed rezoning is approved at Public Hearing, an amendment to
   the Subdivision By-law is needed at the time of enactment to delete the

   category "A" standards established in 1988 for these parcels.

   COMMENTS OF THE APPLICANT

   The applicant has been provided with a copy of this report and has
   provided the following comments:

          "We have reviewed your draft report to Council and discussed it
          with our client.  We were instructed by him to agree with the
          conditions of rezoning, specifically with the condition
          (c)(iii)."